Beckett, Prepare burner & site – Beckett 100 User Manual

Page 7

Advertising
background image

Beckett

Instruction Manual –

Model AFII Oil Burner

Figure 4 - FBX Arrangement

7

AIR

DIAL

SETTING

Firing Rate at

140 psig

AFII 85

AFII 100

AFII 150

0.40 to 0.65

3

-

-

0.60 to 0.75

4

3

-

0.70 to 0.85

5

4

-

0.75 to 1.00

-

5

2

0.95 to 1.20

-

-

3

1.15 to 1.35

-

-

4

1.25 to 1.50

-

-

5

Head

AFII 85

AFII 100

AFII 150

FB0

0.40-0.65 0.55-0.75 0.75-1.00

FB3

0.55-0.85

0.55-1.10

0.85-1.20

FB4 -

0.75-1.10

1.10-1.25

FB6

-

0.85-1.15

1.15-1.35

FIRING

RATE

Prepare burner & site