Beckett, Adjust, pipe, & wire burner, Instruction manual – model afii oil burner – Beckett 100 User Manual

Page 9

Advertising
background image

Beckett

Instruction Manual –

Model AFII Oil Burner

Adjust, pipe, & wire burner

Figure 7 – Typical wiring, R7184 or equivalent primary control

Table 5 – R7184 primary control features

Figure 6 – Typical wiring, R8184G or equivalent primary control

Electrical shock hazard. Disconnect

power

before

servicing.

Electrical shock hazard. Disconnect

power before servicing.

DANGER

DANGER

SK9359

SK9437

Feature

R7184A

R7184B

R7184P

Interrupted ignition

YES

YES

YES

Limited reset, limited recycle

YES

YES

YES

Diagnostic LED, cad cell indicator

YES

YES

YES

Valve-on delay

YES

YES

Burner motor-off delay

YES

Alarm contacts

Optional







9

Advertising
This manual is related to the following products: