Installation instructions continued, Electrical and supply connections, cont’d, Step 8 – Bradley Smoker EXPRESS CRS-3/IR User Manual

Page 8

Advertising
background image

Installation Instructions continued . . .

Step 8:

Electrical and supply connections, cont’d.

6. Check the temperature when approximately 1.0 GPM water flow

is reached and adjust if necessary (the range of the valve is
95°F–115°F (35°C–43°C). To adjust the temperature, follow the
procedure below:

• Loosen temperature locking nut with wrench.

• Using a blade screwdriver, turn the adjustment stem

counterclockwise to increase the temperature or clockwise to
decrease the temperature (see Figure 7).

• Once desired temperature is reached, tighten nut to prevent

temperature change.

Express

®

Crescent

®

Lavatory System - CRS-Series

CRS-2/IR, CRS-3/IR

Installation Instructions

8

2/8/07

Bradley Corporation • 215-1330 Rev. K; EN 06-915

Installation Instructions continued . . .

Figure 6b

TRANSFORMER

CIRCUIT PLUG

WHITE SPADE

TERMINALS

BLACK SPADE

TERMINAL

GREEN SPADE
TERMINAL

BLACK SUPPLY TUBE

(FROM SPRAYHEAD)

RED SPADE
TERMINAL

RED SUPPLY TUBE
(FROM SPRAYHEAD)

GREEN SUPPLY TUBE
(FROM SPRAYHEAD)

COMPRESSION
NUT (110-231)

VERNATHERM™

THERMOSTATIC

MIXING VALVE

SENSOR CIRCUIT

PLUG

SUPPLY INLET

TEMPERATURE

ADJUSTMENT

STEM

TEMPERATURE

LOCKING

NUT

Figure 7

Advertising