9
GB
IMPORTANT!
Remove all transporta-
tion safety components.
Setting up
• Standard EN 378 specifies that the room in which you install your
appliance must have a volume of 1 m
3
per 8 g of R 600a refriger-
ant used in the appliance, so as to avoid the
formation of inflammable gas/air mixtures in
the room where the appliance is located in
the event of a leak in the refrigerant circuit.
The quantity of refrigerant used in your ap-
pliance is indicated on the type plate on the
inside of the appliance.
• Only use the appliance when it is installed.
•
Do not cover ventilation openings
or grille.
Saving energy
- Always ensure good ventilation. Do not cover ventilation openings
or grille.
- Always keep fan louvres clear.
- Do not place appliance in areas of direct sunlight or next to a
stove, heater or similar object.
- The energy consumption depends on the installation conditions,
e.g. the ambient temperature.
- Keep the time the appliance is open to a minimum.
Climate rating
The climate rating indicates the room tem-
perature at which the appliance may be
operated in order to achieve full refrigeration
performance.
The climate rating is indicated on the type
plate.
The position of the type plate is shown in
the section entitled Description of the appliance.
Climate rating
Room temperature
SN
+10°C to +32°C
N
+16°C to +32°C
ST
+16°C to +38°C
T
+16°C to +43°C
SN-ST
+10°C to +38°C
SN-T
+10°C to +43°C
Do not operate the appliance outside the speci-
fied room temperature range.
Electrical connection
Only operate the appliance with alternating current (AC).
The permissible voltage and frequency are indicated on the type
plate. The position of the type plate is shown in the section entitled
Description of the appliance.
The socket must be properly earthed and protected by a fuse.
The tripping current of the fuse must be between 10 A and 16 A.
The socket must not be situated behind the appli-
ance and must be easily accessible.
Do not connect the appliance using an exten-
sion cable or extension socket.
Do not use stand-alone inverters (conversion
of direct current to alternating/three-phase cur-
rent) or energy-saving plugs. Risk of damage
to the electronic control system!
• Do not use electrical appliances inside the appli-
ance.
• The appliance is designed for use in enclosed
areas. Do not operate the appliance outdoors or
in areas where it is exposed to splash water or
damp conditions.
• The LED light strip illuminates the interior of the
appliance. It is not suitable for lighting a room.
• When transporting or operating the appliance at
an altitude of more than 1500 m above sea level,
the glass pane in the door can break due to the
reduction in air pressure. Broken fragments are