1installing the appliance, Putting into operation – Liebherr UIK 1550 Premium User Manual

Page 6

Advertising
background image

Fig. 6 for recess height 820 or 870 mm

A = Height of recess

B = Height of unit plinth

C = Height of unit door

D = Base height of cut-away unit plinth

Recess

height A

Height of unit

plinth B

Height of unit

door C

Base height of

unit plinth D

820 mm

100 mm

716 mm

100 mm

820 mm

170 mm

646 mm

100 mm

870 mm

150 mm

716 mm

150 mm

870 mm

220 mm

646 mm

150 mm

Note

u

Before assembling the door of the unit, make sure that the

admissable weight of the unit door is not exceeded.

u

Otherwise damage to the telescopic rails and resultant

malfunction cannot be ruled out.

Model

Max. weight of unit

door

UIK

10 kg

4.3.1 Installing the appliance

u

Detach the connecting cable from the rear of the appli-

ance, removing the cable holder at the same time

because otherwise there will be vibratory noise!

u

Lay the connecting cable with

the help of a string in such a

way that the appliance can be

easily connected after fitting.

Fig. 7

Slide in and align the appliance:

NOTICE

Risk of harm to flooring susceptible to damage!

u

Place a strip of cardboard under the height-adjustable feet,

approx. 10 cm x 60 cm, one at either side. Cut the strips out

of the packaging. For opening heights less than 826 mm,

use strips of a firm but thin material.

u

After the appliance has been slid in, remove the strips.

Fig. 8

u

Pull the plinth panel forwards to remove it.

u

Slide the appliance

into the recess.

w

The distance of the

front edge of the

side wall of the

kitchen unit to the

appliance body is

41.5 mm all the

way round.

Fig. 9

For units with door stop components (knobs, sealing

lips etc.):

u

Deduct the extra dimension (depth of the door stop compo-

nents) from the 41.5 mm depth of insertion.

u

Align the appliance by adjusting the feet so that it stands

straight: Extend the rear height-adjustable feet by turning

the screws

Fig. 8 (3)

. If the front height-adjustable feet are

extended, turn them using a screwdriver. If the front height-

adjustable feet are retracted, then extend them using an 8

mm Allen key. The appliance should be slightly clamped in

the recess, between floor and worktop!

Fig. 10

u

Insert foam element

Fig. 10 (8)

- functionally important for

separate air currents!

u

Re-attach the plinth panel

Fig. 10 (2)

and pull it forwards

until the front edge of the ventilation grille and the unit plinth

are planar!

Fig. 11

Putting into operation

6

* Depending on model and options

Advertising