1 and 10.

¾ Forward Delay Time (4-30): the number of seconds a port waits

before changing from its Rapid Spanning Tree Protocol learning

and listening state to the forwarding state. Enter a value between 4

and 30.

[NOTE]

1. Use the following rule to configure the MAX Age, Hello Time, and

forward Delay Time

2 x (Forward Delay Time value –1) > = Max Age value >= 2 x (Hello

Time value +1)

2. If the configuration is not saved, it will be lost when the switch is

powered down.