[NOTE]

1. When X-Ring function is enabled, disable the RSTP function. X-Ring

and RSTP cannot exist at the same time.

2. If the configuration is not saved, it will be lost when the switch is powered

down.

„ Security

In this section, you can configure 802.1x and MAC address table.

802.1X/Radius Configuration

802.1x is an IEEE authentication specification that allows a client to connect

to a wireless access point or wired switch but prevents the client from

gaining access to the Internet until it proves authority by providing a user

name and password, which is verified by a separate server.

System Configuration

1. IEEE 802.1x Protocol: Enable or disable 802.1x protocol.

2. Radius Server IP: Enter the Radius Server IP address.

3. Server Port: Enter the UDP destination port for authentication requests

to the Radius Server.

4. Accounting Port: Enter the UDP destination port for accounting

requests to the Radius Server.

5. Shared Key: Enter an encryption key for use during authentication

sessions. This key must match the encryption key used on the Radius

Server.

6. NAS, Identifier: Enter the identifier of the radius client.

7. Click

Apply

.

Advertising