15

5.0 MAINTENANCE


REMOVAL OF SCALE DEPOSITS

WARNING: Read and follow instructions on the CLR bottle. Use
plastic or rubber gloves to avoid skin contact. IF CLR comes in
contact with skin, rinse and clear water.



1. Drain steam generator tank by setting ON/OFF switch to off. Set cooking timer to

“OFF”.


2. Set switch to de-lime. This closes drain valve.

3. Unscrew plug in deliming port at rear of unit. Insert hose in delime fitting. Pour 28

ounces of solution into generator slowly to avoid spillage. Remove hose. Screw plug
into deliming fitting so it seals tightly.


4. Allow steamer to remain in ready cycle for ½ hour then turn ON/OFF switch off and

allow generator to drain.


5. Flush cycle. Turn ON/OFF switch to on. When ready light comes on, switch to off to

flush generator. Repeat this step three times to completely flush generator.

6.

Clean exterior and interior. Use a mild solution of soap and water. Rinse with clean
water. Dry with a soft clean cloth. Leave compartment door open when not in use.

7.

The steamer is now ready for use or turn off for overnight shutdown.