1.0 SERVICE CONNECTIONS

28

[7

11

]

6

[1

52

]

1.

5

[3

8]

1

[2

5]

5

[1

27

]

2.

62

[6

7]

16

.6

2

[4

22

]

58

.7

5

[1

49

2]

S

C

-7

E

88

.5

[1

74

0]

S

C

-1

0E

SC

-7

E

SC

-1

0E

19

.8

8

[5

05

]

19.5 [495]

2.19 [56]

2.19 [56]

REAR FLANGED FOOT DETAIL

7/16" [11mm] HOLES

ON 2.5 [63] B.C.

2 EQUALLY SPACED

Ø

C

ELECTRICAL CONNECTION: 1-1/8" hole for electrical connection. Rating to be as specified on data plate.

DRAIN: 1"IPS to open floor drain. No solid connection. Use copper only, 24" length before open air gap opening (No bends or elbows).

GENERATOR WATER: 3/8" O.D. tubing at 25-50 PSI (170-345 kPa)

CONDENSING WATER: 3/8" O.D. tubing at 25-50 PSI (170-345 kPa)

WATER QUALITY STATEMENT

WATER QUALITY IS THE MAJOR FACTOR AFFECTING THE PERFORMANCE OF YOUR APPLIANCE. IF YOU ARE UNSURE OF WATER
QUALITY, CONSULT A LOCAL WATER TREATMENT SPECIALIST AND HAVE THE WATER ANALYZED. YOUR WATER SUPPLY MUST BE

TOTAL DISSOLVED SOLIDS
TOTAL ALKALINITY
SILICA
CHLORIDE
pH FACTOR

WATER WHICH FAILS TO MEET THESE STANDARDS SHOULD BE TREATED BY INSTALLATION OF A WATER CONDITIONER.
FAILURE OR MALFUNCTION OF THIS APPLIANCE DUE TO POOR WATER QUALITY IS NOT COVERED UNDER WARRANTY.

LESS THAN 60 PPM
LESS THAN 20 PPM
LESS THAN 13 PPM
LESS THAN 1.5 PPM
7.0-8.5

WITHIN THESE GENERAL GUIDE LINES:

9 [229]

16

.7

5

[4

25

]

33

[8

38

]

1.

38

[3

5]

24 [610]

1.

12

[2

9]

27

.3

8

[6

95

]

1/2-NPT DELIME INLET

27

.6

9

[7

03

]

2.

19

[5

6]

3.94 [100]

3 [76]

1.75 [45]

ELECTRICAL CHARACTERISTICS

SC-7E

MODEL

SC-10E

208V

66.6

48.6

63

45.9

57.8

42.1

36.5

26.6

21.1

28.9

kW

17.5

24 - Std

3

3

PHASE

220V

240V

380V

480V

AMPS PER LINE

83.3

78.7

72.2

45.6

36.1

30 - Opt

3

Advertising