1.1.4. Send Command

a.

The structure of Command (EX. input

select) send to Target (Philips PDP) like as
below (Table 9)

Byte0

0xBE

Magic

Byte1

0xEF

Number

Byte2

0x02

Packet Type

Packet Header

Byte3

0x06

Packet size (Low)

Byte4

0x00

Packet size (High)

Byte5

0x80

CRC (Low)

Byte6

0xC7

CRC (High)

Byte7

0xC9

Virtual

Byte8

0x00

Event ID

Packet Payload

Byte9

0x00

Byte10

0x00

Parameter

Byte11

0x00

Byte12

0x00

Table 9

b. Target return to Host (PC) Ack like as below

Table 10

Ack

Byte0

0x06

ACK