6. Power Management

6. Power

Management

If you have VESA DPM compliance display card
or software installed in your PC, the monitor
can automatically reduce its power consumption
when not in use. If an input from a keyboard,
mouse or other input device is detected,
the monitor will 'wake up' automatically. The
following table shows the power consumption
and signaling of this automatic power saving
feature:

3RZHU 0DQDJHPHQW 'HÀQLWLRQ

VESA

Mode

Video H-sync V-sync

Power Used

LED Color

Active ON Yes

Yes

220B4LPY: 20.4W

(typ.)

220B4LP: 19.6W

(typ.)

White

Sleep

(Standby)

OFF

No

No

0.1W (typ.)

White
(blink)

Switch Off

OFF

-

-

0 W (typ.)

OFF

The following setup is used to measure power
consumption on this monitor.

‡

Native resolution: 1680 x 1050

‡

Contrast: 50%

‡

Brightness: 250 nits

‡

Color temperature: 6500k with full white
pattern

Note

This data is subject to change without notice.