Automatic Power Saving

SCANNING

• Horizontal scanning

30 - 86KHz

• Vertical scanning

50 - 160 Hz

VIDEO

• Video dot rate

180 MHz

• Input impedance

- Video

75 Ohm

- Sync

1.8 kOhm

• Input signal levels

0.7 Vpp

• Sync input signal

Separate sync

• Sync polarities

Positive and negative

WHITE COLOR TEMPERATURE

Chromaticity CIE coordinates:

• at 9300 degrees K

x = 0.283 / y = 0.297

• at 6500 degrees K

x = 0.313 / y = 0.329

• at 5500 degrees K

x = 0.332 / y = 0.347

sRGB

x = 0.313 / y = 0.329

sRGB

sRGB is a standard for ensuring correct exchange of colors between different devices (e.g.
digital cameras, monitors, printers, scanners, etc.)

Using a standard unified color space, sRGB will help represent pictures taken by an sRGB
compatible device correctly on your sRGB enabled Philips monitors. In that way, the colors
are calibrated and you can rely on the correctness of the colors shown on your screen.

Important with the use of sRGB is that the brightness and contrast of your monitor is fixed to
a predefined setting as well as the color gamut. Therefore it is important to select the sRGB
setting in the monitor's OSD.

To do so, open the OSD by pressing the MENU button on the front of your monitor. Use the
down button to go to Color temperature and press MENU again. Then move the down button
to go to sRGB and press MENU again.

Exit this OSD.

After this, please don't change the brightness or contrast setting of your monitor. If you
change either of these, the monitor will exit the sRGB mode and go to a color temperature
setting of 6500K.