Hp series portable pumps – Hale HP Series User Manual

Page 16

Advertising
background image

HP SERIES
PORTABLE PUMPS

USER OPERATION AND MAINTENANCE

16

10. RECOIL STARTER: The recoil starter

is located on the engine behind the

protective grill. To gain access to the

recoil starter the pump panel below

the instrument panel must be

opened on the portable models.

11. PUMP DRAIN: The pump drain is a

petcock type valve located below

the suction connection of the pump

at the lowest point of the pump

volute. This valve is used to drain all

water from the pump after use and

prior to storage.

12. DISCHARGE VALVE DRAIN: The

discharge valve drain is a petcock

type valve located below the outlet

of the discharge valve. This valve is

used to relieve the pressure in the

discharge hose before disconnecting

the hose.

13. LIGHT AND CHARGING SOCKET:

An optional marine grade light and

charging socket is located on the top

cover of the HP series portable

pumps. This socket has a waterproof

plug type cover that is removed to

enable use of the optional light mast

(Hale P/N 200-2100-02-0). The socket

is also used to plug in the optional

trickle charger (Hale P/N 200-0750-01-

0) to maintain the charge on the

pump's 12 volt battery.

14. EXHAUST PRIMER ASSEMBLY: The

exhaust primer assembly is located

on the outlet of the muffler. Located

on the exhaust primer assembly is a

1/4 turn valve. Under normal

operation conditions, when the

pump is being operated from draft,

the handle on the 1/4 turn valve will

be in the open position (in-line with

the tubing). When the pump is being

DISCHARGE VALVE

DRAIN PETCOCK

PUMP DRAIN PETCOCK

FUEL PRIMER BULB

FUEL FILTER

Advertising