6 routine maintenance, 1 maintenance procedures, After each use – Hale CAFS Attack User Manual

Page 57: Monthly, Every two (2) months, Routine maintenance, Maintenance procedures, 6routine maintenance

Advertising
background image

57

CAFS Bottled-Air Operator/s Guide
p/n: 029-0020-85-0

Ro u tine M ain te n an ce

❑

6

Routine maintenance

6.1

MAINTENANCE PROCEDURES

After each use

❑

Inspect wiring, hoses, flow sensors and connections for tightness, cor-
rosion, leaks and/or damage. (See Section 4, heading 4.7 “Plumbing,”
on page 31.)
Also see Section 4, heading “Electrical” on page 38.

❑

Verify status of the CAFSAttack air filter element. See heading 6.2
“Replace Filter Element” on page 58.

❑

Clean inspect the CAFSAttack system for after each use.

❑

Verify status (charge) of the air-bottle cylinders. (See Section 2, head-
ing “Intelli-Tank Air Level Indicator,” on page 22.).
Refill as needed.
(See Section 2, heading “Air Bottle FILL Coupling,” on page 22.)

❑

Flush the foam pump if a non-approved foam concentrate is used.
Also see “Appendix B: Foam Concentrate Compatibility” on page 61.

❑

See your specific FoamLogix manual, provided with the system, for
additional maintenance procedures.

Monthly

❑

See your specific FoamLogix manual, provided with the system, for
maintenance procedures.

❑

Verify air flow calibration. (See Section 5 “Preset calibration,” on page
51.)

❑

Visually and functionally inspect the CAFSAttack system for leaks and
proper system operation.

❑

Ensure that all shut-off valves and switches function properly.

Every Two (2) Months

❑

See your specific FoamLogix manual, provided with the system, for
maintenance procedures.