SECTION 2 DESCRIPTION

The Hale FoamLogix 2.1A and 1.7AHP Foam

Proportioning Systems are completely engineered,

factory matched foam proportioning systems that

provides reliable, consistent foam concentrate

injection for Class “A” foam operations.

Hale FoamLogix Foam systems accurately deliver

from 0.1% to 10.0% (up to the capacity of the foam

pump) foam concentrate through a check valve/

injector fitting, directly into the water discharge

stream. It is then fed as foam solution into a

standard fog nozzle, an air aspirated nozzle, or

CAFS equipment, through the apparatus discharge

piping. A properly configured and installed foam

system with Hale recommended components

virtually eliminates contamination of the booster

tank, fire pump and relief valve with foam

concentrate.

ROTARY PLUNGER PUMP

The heart of the Hale FoamLogix 2.1A and 1.7AHP

systems are an electric motor driven rotary plunger

pump. The pump is constructed of anodized

aluminum and stainless steel and is compatible

with most Class “A” foam concentrates. The pump

is close coupled to the electric motor thereby

eliminating maintenance of an oil filled gearbox.

A relief valve mounted on the foam pump and

con structed of brass, protects the foam pump

and foam concentrate discharge hoses from over

pressurization and damage.

CONTROL UNIT

The control unit, mounted on the operator panel, is

the single control point for the FoamLogix system.

Pressing the ON button starts foam concentrate

injection. A super bright digital LED display shows

the:

Water flow rate

Total water flow

Foam concentrate injection percentage

Total foam concentrate used, depending on the

display mode selected.

A bar graph indicates the approximate system

capacity being used. Adjustment of the foam

concentrate injection rate is accomplished by

pressing the appropriate button.

The control unit display also warns the operator if

errors or abnormal operations occur in the system,

such as low foam level.

WATER FLOW SENSOR

Foam concentrate injection rate is controlled by

a computer chip in the control unit for accurate,

repeatable, reliable foam concentrate injection. A

water flow sensor constantly monitors water flow

through the discharge piping. The informa tion from

the flow sensor is provided to the control unit by

a shielded cable. When the FoamLogix system is

activated at the control unit a signal is sent through

the control cable to the distribution box to begin

foam concentrate injec tion. The distribution box then

provides power to the electric motor. As the motor

rotates the pump, foam concentrate flows through

the foam pump discharge to the one piece check

valve/ injector fitting into the water discharge stream.

Note: All Hale FoamLogix Foam systems

require a flow sensor for operation.

FEED BACK SENSOR

A feedback sensor in the foam pump discharge

measures foam concentrate flow. The water flow

rate and foam concentrate flow rate are con stantly

compared by the computer chip in the control unit.