FoamLogix, Model 2.1A and 1.7AHP Class “A”

Electronic Foam Proportioning Systems

44

Control Unit

The control unit mounts in the operator panel of

the apparatus. The display is secured with four #8

socket head screws. (See Figure 19 “Control Unit

Mounting Dimension” for mount ing dimensions).

The display requires a 7” (178mm) minimum

clearance from the back of the operator panel to

allow proper connection of cables. Once the control

unit is mounted on the operator panel, attach the

14 pin AMP connector on the cable assembly to the

back of the display. Referring to Figure 20: “Control

Harness Connections” and Figure 21: “System

Power and Ground Connections,” on page 45, make

connections to the motor controller box and flow

sensor.

Notes: Ensure that the panel where the control unit

is mounted has an adequate ground. For stainless

steel and vinyl coated panels a ground strap ½ inch

(12mm) wide must be attached from one of the four

screws holding the control unit in place to the frame

of the fire truck to ensure adequate grounding.
Allow a service loop to prevent “pulling” of the wires

or connectors during body and frame flex.

Display Unit Power and Ground

Connections

Power must be connected directly to the display

unit. The power and ground connec tion is the 2-pin

packard connector on the 12”(305mm) long pigtail of

the harness (see Figure 20 on page 45).

The mating harness provided is approxi mately 18”

(457mm) long. If additional wire length is required,

use minimum 16 AWG type SXL, or GXL (SAE

J1128) wire.

Connect the black (B) wire to a chassis ground

stud. Protect the ground connection from

corrosion.

Connect the red (A) wire to the power supply. It

is recommended to connect the power wire to

a minimum 5 AMP, fused, dedicated circuit. If a

dedicated circuit is not available, the power lead

may be connected to a termi nal where there is

not a HIGH current load. Acceptable additional

components powered from this terminal include

ENFO IV, Gover nor, Tank Level Gauge, Etc.