TROUBLE-SHOOTING CHART

18

Fluid Management

®

An excessive amount of
vibration occurs.

if mixer is out of balance.

• Balance by adjusting the

legs.

if adjustable leg is broken or dam-
aged.

• Replace adjustable leg.

The POWER light is on
and nothing happens.

if the motor connections.

• Tighten motor

connections as required.

for broken wire motor cabling.

• Replace motor cable as

needed.

for faulty contact block on power

switch.

• Replace motor cable as

needed.

for problem with the motor.

• Replace motor.

for problem with printed circuit
board.

• Call Customer Service.

Replace printed circuit
board.

The POWER light does not
turn on and nothing hap-
pens.

for problem with POWER switch,
light or operator button.

• Replace as needed.

The POWER light does not
turn on and mixer runs nor-
mally.

for problem with POWER switch,
light.

• Replace as needed.

The mixer starts slowly
and then increases to nor-
mal speed in a few sec-
onds.

shake motor V-belt tension.

• Adjust the shake motor V-

belt tension.

The mixer speeds up and
slows down.

if the door is making partial con-
tact with the safety switch.

• Adjust safety switch.

for a damaged wire in motor
cabling.

• Replace motor cable.

Advertising