SERVICING AND REPAIR

22

Fluid Management

®

CHANGING OR ADJUSTING V-BELT

Read all of the following instructions. If you have any doubt about
performing these procedures, please contact Customer Service at Fluid
Management. Refer to the Parts Section for component identification and
location.

1. Unplug the power cord from the electrical outlet.

2. Close front cover of the machine.

3. Release the two (2) latches as shown and open rear of machine.

Figure 6 Opening Rear of Machine

4. The belt tension is adjustable with an adjustment bolt and locking nut.

To loosen or tighten the tension, back off the locking nut and adjust with
adjustment bolt as shown.

5. To replace the belt, back off the locking nut and loosen with adjustment

bolt as shown. Remove belt and install replacement as required.

LATCHES

OPEN

OPEN