3 operation safety, Electrical hazards, 3 operation safety -3 – JLG Telehandler Personnel Work Platform User Manual

Page 11: Electrical hazards -3, 3 operation safety electrical hazards

Advertising
background image

1-3

31200160

1.3

OPERATION SAFETY

Electrical Hazards

• This machine is not insulated and does not provide protection from contact or

proximity to electrical current.

• Maintain safe distance from electrical lines, apparatus or any energized

(exposed or insulated) parts according to the Minimum Safe Approach Distance
(MSAD).

• Allow for machine movement and electrical line swaying.

• Maintain a clearance of at least 10 ft (3 m) between any part of the machine and

its occupants, their tools and equipment from any electrical line or apparatus
carrying up to 50,000 volts. One foot additional clearance is required for every
additional 30,000 volts or less.

• The minimum safe approach distance may be reduced if insulating barriers are

installed to prevent contact and the barriers are rated for the voltage of the line
being guarded. These barriers shall not be part of (or attached to) the machine.
The minimum safe approach distance shall be reduced to a distance within the
designed working dimensions of the insulating barrier. This determination shall
be made by a qualified person in accordance with the employer, local or
governmental requirements for work practices near energized equipment.

Voltage Range

(Phase to Phase)

MINIMUM SAFE APPROACH

DISTANCE (MSAD)

0 to 50 KV

10 ft (3 m)

Over 50 KV to 200 KV

15 ft (5 m)

Over 200 KV to 350 KV

20 ft (6 m)

Over 350 KV to 500 KV

25 ft (8 m)

Over 500 KV to 750 KV

35 ft (11 m)

Over 750 KV to 1000 KV

45 ft (14 m)

Note: This requirement shall apply except where employer, local or
governmental regulations are more stringent.

OAB0010