6 testing & final assembly, Testing the air locker actuation, Re-sealing & filling the differential – ARB RD168 User Manual

Page 41

Advertising
background image

6 Testing & Final Assembly

39

6.3

Testing the Air Locker Actuation

To test that your air system, electrical system, and your Air Locker
differential is functioning correctly:

F

Support the vehicle such that the wheels are free to rotate (e.g., on

axle stands, a chassis hoist, etc.)

F

Leave the parking brake off, the transmission in neutral, and the Air

Locker switch ‘OFF’.

F

Turn the ignition to the ‘ON’ position (leaving the motor off). The

large illuminating symbol on the Air Locker switch cover should be
‘OFF’.

F

Turn the compressor (or alternate air source) on to charge the air

supply up to its maximum pressure.

F

While supporting the drive shaft flange, rotate one wheel by hand.

F

The wheel should rotate freely and the opposite wheel should be

turning in the opposite direction without any resistance or
mechanical noise from within the differential.

F

Turn the Air Locker switch to the ‘ON’ position. The illuminated

symbol on the switch cover should light up.

F

Rotate the same wheel again.

F

Both wheels should rotate together.

F

Turn the switch off again.

F

Rotate the same wheel.

F

The wheels should again rotate in opposite directions.


6.4

Re-Sealing & Filling the Differential

NOTE : Consult the ARB Air Locker Operating & Service

Manual for recommendations on differential lubricant
specifications.

F

Replace the differential cover using gasket sealant or a new

standard differential cover gasket for your make of vehicle.

F

Refill the differential until level with the filler hole.

F

Rotate the differential center 2 full turns.

F

Check the oil level and add oil if necessary.

F

Replace filler plug (apply thread sealant to filler plug before

inserting if it is a threaded type plug).

F

Wipe differential housing clean of any oil or grease which may

collect dirt or other abrasive particles.