Air compressor – ARB RD114 User Manual
Page 22
4 Installing the Air System
20
4.1
Mounting the Solenoid
4.1.1
Connection to an ARB Air Compressor
(Fig.11.)
c Remove one of the 1/8” BSP plugs from its port in the compressor
manifold.
c Apply Teflon paste to the nipple (1/8” X 1/8” BSP) and insert it into
the port and tighten.
c Apply Teflon paste to the free end of the nipple.
c Assemble the inlet port side of the solenoid (stamped with a ‘1’)
onto the nipple and tighten. The solenoid should be rotated into a
position that does not obstruct any other ports on the compressor
manifold.
NOTE : The solenoid exhausts compressed air through the
center of the black retaining cap when the
Air Locker
is disengaged. Make sure this orifice cannot be
obstructed.
c Apply Teflon paste to the threads of the 5mm push-in fitting and
assemble it into the solenoid outlet port (stamped “2”) and tighten.
Figure 11.
ARB
Air Compressor