4 Installing the Air Locker

16

1mm

4.5

Modifying the Bearing Cap


c A hole must be drilled in the seal housing bearing cap for the seal

housing tube to pass through.

c Measure and mark a location on the bearing cap that would allow a

6.35mm [¼’’] hole to be drilled with 1mm [0.039”] clearance from
the edge of the hole and the machined bearing recess. (Fig.10.)

Figure 10.










NOTE :

Take time and double check when taking your
measurements, as bearing caps are custom fitted to
the axle housing and cannot be replaced.


c Hold the bearing cap steady for drilling in a soft jawed vice clamp.

NOTE :

Do not apply too much clamping pressure with the
vice. The bearing cap may be damaged.

c Using a pedestal drill, drill a 6.35mm [¼’’] hole through the bearing

cap where the position has been marked.

c Debur both ends of the drilled hole to remove any sharp edges.