Heater specifications, Model – L.B. White 170 Dual Fuel User Manual
Page 4
CS170
Maximum Input (kW)
49.8
2056
MAX.
3.36
MIN.
2.74
PROPANE
1.34
NATURAL GAS.
1.37
PROPANE (kg)
3.57
NATURAL GAS (m
3
)
4.81
Ball Bearing
246 W / 1,100 RPM
115/60/1
7.3
5.0
78.1 x 46.3 x 71.8
TOP
.3 m
SIDES
.3 m
BACK
.3 m
BLOWER
OUTLET
GAS
SUPPLY
70.3
73
Minimum Ambient Temperature
in Which Heater May Be Used
Heater Specifications
Motor Characteristics
Propane Gas - 1.83 m
SPECIFICATIONS
Model
Ventilation Air Required to Support
Combustion (m3/ hour)
Net Weight (kg)
Shipping Weight (kg)
Electrical Supply (Volts/Hz/Phase)
Amp Draw
Dimensions (cm)
L x W x H
Minimum Safe
Distances From
Nearest
Combustible
Materials
STARTING
CONTINUOUS
OPERATION
Fuel Consumption Per Hour
Inlet Gas Supply
Pressure Acceptable at
the Inlet of the Heater for Purpose
of Input Adjustment (kPa)
1.83 m
- 29º C
Burner Manifold Pressure
(kPa)
4