Fig. 6 fig. 7, Fig. 8 – L.B. White 350 Premier User Manual

Page 12

Advertising
background image

C. U

Using IInflatable D

Ducting

CLAMP

DUCT ADAPTER

TABS

DIFFUSER

B. AAttaching EEnd D

Diffuser tto D

Duct

Accessory part 23054

1. Loosen screw on duct clamp so clamp is positioned

over ribs at end of duct.

2. Slide duct adapter into duct end. Duct adapter tabs

must be facing away from duct and are located at 3,

9 and 12 o’clock positions.

See Fig. 5.

3. Tighten screw clamp so adapter is held securely

within duct.

4. Insert tabs of adapter into slots on air diffuser back.

5. Push down on adapter so tabs are seated firmly to air

diffuser.

6. Locate diffuser under side wall. See Fig. 6.

FIG. 6

FIG. 7

TENT DRAPED OVER DIFFUSER

TENT SIDE WALL

TENT DRAPED
WITHIN DIFFUSER
CHANNEL

OPTIONAL AIR DIFFUSER

MATERIAL DRAPED

WITHIN DIFFUSER

CHANNEL

500 GALLON

GAS SUPPLY

(MINIMUM)

MINIMUM SAFE DISTANCE

FROM GAS SUPPLY TO HEATER

IS 6 FEET

TO ALLOW PROPER AIR DISTRIBUTION

FLEXT DUCT MUST NOT HAVE MORE THAN

TWO 90 DEGREE BENDS

MAINTAIN A 10 FOOT CLEARANCE

FROM HEATER TO WALL

DUCT ADAPTER W/ TABS

(FACTORY INSTALLED INTO 12 FT DUCT)

CLAMP

MATERIAL

DRAPED

OVER DUCT

DUCT RING

INFLATABLE DUCT, 100 FT.

DISCHARGE HOLES

POINTED DOWNWARD

(OPTIONAL ACCY 23053)

8 FEET

CLEARANCE

TO GROUND

TYPICAL

CHAIN LOOPED AROUND DUCT

DUCT RING

ROOF SUPPORT

WIRE OR CABLE

(SUPPLIED BY CUSTOMER)

HANGING CLAMP

S-HOOK

CLAMP

FIG. 8

11

10 FEET