Igniter assembly – L.B. White 350 Premier User Manual

Page 18

Advertising
background image

17

IGNITER ASSEMBLY

1. Remove burner access panel. See Fig. 18.

FIG. 18

2. The igniter assembly is located at the top of the

burner casting. Remove the screws securing the

mounting bracket to the burner. See Fig. 19.

FIG. 19

3. Disconnect high voltage ignition lead. Remove the

mounting screws. See Fig. 20.

FIG. 20

The igniter and ground rod should be cleaned during

routine maintenance to maintain proper ignition.

-- Use steel wool or emery cloth.

-- Rub briskly to remove buildup of dust, dirt , and oxide.

Check the igniter’s ceramic base for cracks.

-- Replace the igniter if cracks are found.

SCREWS

IGNITION LEAD END

ELECTRODE GAP IS 1/8 IN
AND CENTERED OVER BURNER PORT

BURNER
PORT

ELECTRODE GAP IS 1/8 IN.

AND CENTERED OVER BURNER PORT

5/32 IN IGNITOR BOTTOM
TO BURNER TOP

SCREWS

MOUNTING
BRACKET

IGNITOR/SENSOR

IGNITOR CABLE

5/32 IN. IGNITER BOTTOM

TO BURNER TOP