Shut-down instructions, Cleaning instructions, Start-up instructions – L.B. White 200 Norseman User Manual

Page 10

Advertising
background image

IGNITER BUTTON

PILOT BUTTON

9

1. Close manual main burner valve on heater.

2. Slowly open the propane gas supply container valve.

3. Fully depress the button on the pilot safety control

valve while pushing the igniter button.

4. Keep the pilot button depressed for about 30

seconds to allow the thermocouple to warm up.

5. Open the manual main burner valve located between

the pilot safety control and burner.

FIG. 3

ATTENTION

On new installations it will take a short time for gas to

purge out any air in the pilot line and hose before the

pilot may be lit.

A. To properly shut heater down after normal use, or

when further use is anticipated:

-- Close manual main burner valve on heater.

B. To properly shut heater down for storage, or when

further use is not anticipated:

1. Close propane gas supply container valve. Allow

heater to burn off remaining gas in its hose.

2. Close manual main burner valve on heater.

3. Disconnect the heater from its gas supply.

Shut-Down Instructions

WARNING

Fire oor EExplosion H

Hazard

Use only your hand to depress the gas control button.

Never use any tools.

If the button will not depress by normal hand pressure,

the control should be replaced by a qualified service

person.

Force or attempted repair may result in a fire or

explosion causing property damage, severe injury, or

death.

1. Before cleaning, close all gas supply valves.

2. The heater should have dir t or dust removed

periodically:

a. Before each use give the heater a general

cleaning using compressed air, a soft brush, or

dry rag, on its case and internal components.

b. At least once a year, give the heater a thorough

cleaning. At this time, remove the burner

assembly and brush and/or blow off the burner

and related components.

WARNING

Do not use a pressure washer, water, or liquid cleaning

solution on any gas controls. Use of a pressure washer,

water, or liquid cleaning solution on the control

components can cause severe personal injury or

property damage due to water and/or liquids:

* On gas control valves causing corrosion which

can result in gas leaks and fire or explosion from

the leak.

Clean all components of the heater with pressurized air, a

dry brush or a dry cloth.

Cleaning Instructions

WARNING

Fire, B

Burn, aand EExplosion H

Hazard

This heater contains components used in the gas management, and safety systems.

Such components may become inoperative or fail due to dust, dirt, wear and aging.

Periodic cleaning and inspection as well as proper maintenance are essential to avoid serious injury or property

damage.