Problem solving, Introduction – Fast & Fluid SK350 User Manual

Page 14

Advertising
background image

Fast & Fluid Management – SK350

V 2.0

page 14

Problem solving

Introduction

Before calling your machine supplier or Service Department, please check whether you can solve the
problem yourself. If you cannot, then call the Service Department for advice. Have the model number and
serial number at hand (these can be found on the silver sticker at the back of the machine). Use the Problem

Solving chart below to judge whether you can solve a problem yourself or whether you need to call in the
Service Department. On no occasion remove side panels yourself, this may only be done by trained service
personnel.

Attention! MOVING PARTS CAN CAUSE INJURY. Always turn off
power (e.g. by pressing emergency stop) before accessing
moving parts.

Problem Solving

Symptom

Cause

Action

Main power supply is
present but the machine
does not work

Door of the machine is open

Close the door

Emergency stop is active

Turn emergency stop clockwise

Machine is overloaded

Unload (max 35 kg)

Fuse blown (on the socket)

Shut power off and replace fuse

(see page 15)

Door switch is defective

Call service

Keyboard is defective

Call service

Fuse F3= 1A blown (on the
main board)

Call service

Main board is defective

Call service

Extreme vibration when
mixing

Machine incorrectly loaded

Place load in can table center

Machine is not level

Level the machine

Adjustable feet set incorrectly

Adjust all feet so they support
the machine properly and lock

them into position.

Suspension struts are defective Call service

Clamping plate goes down,
then nothing happens

Fuse F2 = T8A blown (on the
main board)

Call service

Main board is defective

Call service

Shaker motor is defective

Call service

Start relais or capacitors are
defective

Call service

Clamping plate jammed

Call service

Clamping plate will not go

down

Clamping motor is defective

Call service

Cable of the clamping motor is

defective

Call service

Main board is defective

Call service

Door switch defective

Call service