For your safe flight page 29 – J.P. Instruments EDM 760 Pilots Guide User Manual

Page 33

Advertising
background image

In the ALL (All) position, the EDM-760 both installed
temperature and fuel flow measurements are displayed in the
digital display in either the Automatic or Manual indexing
modes or during the pilot procedure.

Start Up Fuel
After initial self-test, you will be asked to inform the EDM-760 of start up
fuel. The EDM-760 will display

FUEL for one second, and then flash

FILL? N until any button is pressed. If your aircraft has tank fill tabs and
no auxiliary tanks, you can use the auxiliary tank feature to select either
filling to the tank tabs or topping the tank. See “Main Tank Capacity”

and “Auxiliary Tanks” beginning on page 47 to program the EDM-760
for this feature. The EDM-760 does not differentiate fuel flow between
the main and auxiliary tanks; it considers only total fuel in the aircraft.
During flight you may also inform the EDM-760 of startup fuel using
the pilot program mode, page 37,
if you forgot to do so at start up.

main tank

auxiliary tank

main tank with tab

tab

Auxiliary capacity

Main capacity

Refer to the column in the chart below corresponding to your fuel tank
configuration. Tap the LF button to select one of the four following
fueling choices on the left column of the chart.

LF to
choose

Main tanks only, no

tabs

Main tanks

with tabs

Main & Auxiliary

tanks

FILL? N

Did not add any fuel since last shutdown.

FILL
75

GAL

Topped the main
tanks.

Filled only
to the tabs.

Topped the main tanks.
If some additional fuel is
added to the auxiliary
tanks, you will input this
next when

.0 GAL is

displayed

FILL
I20

GAL

(not available)

Topped the
main tanks.

Topped both the main
and auxiliary tanks.

FILL +

GAL

Did not top, but added additional fuel to the aircraft, or
removed fuel from the aircraft.

For Your Safe Flight

Page 29

Advertising