PHCC Pro Series ST1050 Sump Pump User Manual

Sump pumps instruction manual & safety warnings, Important safety instructions, Items included

Advertising
background image

Specifications

1/3 HP Model ST1033

1/2 HP Model ST1050

GPH @ 0’

4100

5300

GPH @ 10’

2770

3630

G/Wh

6.1

6.3

Pump diameter

7.375”

9.75”

Volts

115V, 60Hz

115V, 60Hz

Amps

3.8

4.8

Important Safety Instructions

SAVE THESE INSTRUCTIONS. This manual contains important SAFETY WARNINGS and
OPERATING INSTRUCTIONS for the Pro Series pumps. You will need to refer to it before
attempting any installation or maintenance.
ALWAYS keep these instructions with the unit so that they will be easily accessible.
Failure to read and follow these warnings and instructions could result in property
damage, serious injury, or death.

ALWAYS disconnect the pump from the power source before servicing or making

adjustments.

NEVER handle the pump or motor with wet hands or when standing on a wet or damp

surface while the pump is plugged into the power source.

MAKE SURE THERE IS A PROPERLY GROUNDED RECEPTACLE AVAILABLE. This pump is

wired with a 3-prong grounded plug. To reduce the risk of electric shock, be certain that
it is only connected to a properly grounded, 3-prong receptacle (preferably with ground
fault circuit interrupt). If you have a 2-prong receptacle, have a licensed electrician
replace it with a 3-prong receptacle according to local codes and ordinances.

NEVER bypass grounding wires or remove the ground prong from the plug.

DO NOT use an extension cord. The electrical outlet should be within the length of the

pump’s power cord, and at least 4 feet above the floor level to minimize potential
hazards from flood conditions.

DO protect the electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid

kinking the cord.

MAKE SURE the supply circuit has a fuse or circuit breaker rated to handle the power

requirements noted on the nameplate of the pump.

DO NOT use the power cord or strain relief to carry the pump. Use the pump handle.

DO NOT expose the control unit to rain or snow.

DO NOT operate the pump or control unit if it has been damaged in any way.

DO NOT use sump pumps in pits handling raw sewage, salt water, or hazardous liquids.

DO NOT disassemble the pump or control unit. When service is required, contact

Glentronics technical support at 800-991-0466, option 3. Return the product to the
manufacturer for any repairs at the following address:

Glentronics, Inc., 645 Heathrow Drive, Lincolnshire, IL 60069

ƽ CAUTION

ƽ WARNING

Risk of electric shock. To reduce this risk, observe the
following precautions
.

To reduce the risk of hazards that can cause injury or
property damage, observe the following precautions.

Sump Pumps

Instruction Manual &

Safety Warnings

Items included:

Pump

Choice of controller,
float/sensor

Stainless steel hose
clamp

2" x 1-1/2" reducer
adapter (on 1/2 HP
pump only)

You may also
need:

1-1/2” or 2" rigid PVC
pipe to connect to the
existing plumbing

A check valve or union

PVC pipe cleaner and
cement

A surge protector

DFC1 Controller

& Dual Float

1/2 HP Pump

ST1050

1/3 HP Pump

ST1033

Note:

The 1/2 HP pump will accomodate a 2" discharge
pipe. However, most homes have 1-1/2" pipes.
Therefore we have included a 2" x 1-1/2" reducer
adapter with this pump. You may replace your 1-
1/2" discharge pipe with a 2" discharge pipe, and a
2" adapter to obtain the optimum gallons per hour.

1-1/2”

discharge

2”

discharge

USC3 Ultimate Solid

State Controller &

Ultimate Sensor

G/Wh = Gallons per Watt Hour G/Wh = GPH/(Amps x Volts)

Models ST1033 & ST1050

DFC2 Deluxe

Controller

& Dual Float

Advertising