AEM 30-2340 4-Channel Wideband UEGO AFR Controller User Manual
Page 8

Page 8 10-2340 Rev 05 121012
NOTE: THE SERIES 2 EMS DOES NOT USE INFORMATION TRANSMITTED ON
AEMnet FOR 02 FEEDBACK. THE SERIES 2 EMS USES THE ANALOG INPUTS
FOR 02 FEEDBACK. SEE THE SECTION ON ANALOG INPUTS FOR INFORMATION
ON CONNECTING THE ANALOG INPUTS.
NON-AEM PRODUCTS
Each AEMnet connector has 4 pins. The AEMnet pinout is listed below in Table 2.
NOTE: Pin numbers are located at the back of the connector. Non-AEM devices can
connect to the AEMnet by connecting their CAN +/- wires to the CAN+/- wires on the
AEM network. The connectors are shown in Figure 7.
AEMnet Connector
Pin 1
White
CAN +
Pin 2
Green
CAN -
Pin 3
Red
12 Volts
Pin 4
Black
Ground
Table 2. AEMnet Pinout
•
Deutsch DTM04-4P (Receptacle connector)
•
Deutsch 1060-20-0222 (Pins)
•
Deutsch DTM06-4S (Plug connector)
•
Deutsch 1062-20-0222 (Pins)
Figure 7. Connector Assembly
NOTE: the 4 CH UEGO controller has one terminating resistor. If an additional
terminating resistor is needed, one must be installed on the other device.