System Errors

The controller will continuously check for errors; when an error is detected it will be reported to
the user by a flashing sequence of the external LED, as well as a corresponding red flashing
sequence of the status LED. Damage to vehicle or engine may occur if these faults are not
resolved immediately. The water-injection system may not operate properly or at all while an
error condition exists. Please refer to the table below for further information.

# of

Flashes

Error

Description

Controller/Pump Status

Recommended Action

1

Low Fluid

The amount of fluid in the
tank has been detected to be
below the level of the sensor.

- BoostSafe Enabled
- Pump will continue to

run

Refill fluid reservoir.

2

Pump

Open

Circuit

An open circuit has been
detected in the circuit (wiring)
that drives the pump.

- BoostSafe Enabled
- Pump will NOT continue

to run

Check for a blown
controller fuse and pump
wiring for disconnects.

3

Pump

Short

Circuit

A short circuit has been
detected in the circuit (wiring)
that drives the pump.

- BoostSafe Enabled
- Pump will NOT continue

to run

Check pump wiring for
shorts to the chassis.

4

Voltage

Out of

Range

The voltage powering the
controller has been detected
to be outside the range of
8.5V - 16V.

- BoostSafe Enabled
- Pump will NOT continue

to run

Check power connections
to controller and that
vehicle charging system is
operating properly.

5

Frequency

The external input signal was
found to be out of range.

- BoostSafe Enabled
- Pump will NOT continue

to run

Check user selected
mode, and or wiring.