Status Lights

The AEM Pressure gauge has two status lights, see Figure 4. The status light on the
left will flash if an out of range low voltage sensor error is detected. The status light on
the right will flash if an out of range high voltage sensor error is detected. In either
case, the needle will point straight downward to signify an error. See Table 1 for
corrective actions.




Status Light

Fault

Corrective Action

Left

Sensor Wiring and/or sensor

Make sure sensor is

connected, check for

broken wires

Right

Sensor and/or sensor wiring

Check for shorted

sensor wires, possible

overpressure condition


Figure 4. Backlighting Adjustment

Table 1. Error Codes

Figure 4. Illuminated Status Lights