AEM 30-6050 Series 2 Plug & Play EMS User Manual
Page 11

Page 11 of 13
Pin # 00-01 Integra / 98-02 Accord / 99-00 Civic AEM EMS 30-6050
I/O
Availability
D1
---
Injector 5
Output Avail, Switched Ground, 1.5A Max
D2
---
Injector 7
Output Avail, Switched Ground, 1.5A Max
D3
---
Idle #1
Output Avail, Switched Ground, 1.5A Max
D4
---
High Side Driver 4 Output
Avail, Switched +12v, 1.5A Max
D5
---
Idle #4
Output
Avail, Switched +12v, 1.5A Max
D6
---
+5V Sensor
Output Avail, 5V sensor reference power
D7
---
EGT #2
Input
Avail, jumper set for 0-5V Input
D8
---
ADCR14
Input Available, 0-5V in, 100k pull up to 5v
D9
---
Sensor Ground
Output
Avail, Sensor Ground
D10
---
CAN1H
---
Dedicated
D11
---
Switch 2
Input
Avail, Switched GND Input
D12
---
Switch 3
Input
Avail, Switched GND Input
D13
---
High Side Driver 3 Output
Avail, Switched +12v, 1.5A Max
D14
---
CAN1L
---
Dedicated
D15
---
Baro Volts
---
Avail, 0-5V input
D16
---
PW 2
Output
Avail, Boost Solenoid Output
*** Important: Wire View of AEM EMS. Reference diagram below for pin location. ***