4.8. Automatic display brightness
The indicators and displays on the TPG+ can be user configured for brightness in both a DAY mode and a NIGHT
mode (see sections 5.2.5 and 5.2.6). The TPG+ utilizes a light sensor on its front panel to determine if it is operating
in DAY or NIGHT mode. The sensitivity of the light sensor is not configurable.
•
When the light sensor detects light the TPG+ is set to DAY mode.
•
When the light sensor detects a low light condition the TPG+ is set to NIGHT mode.
The transition from DAY to NIGHT (or vice-versa) takes thirty (30) seconds.
Note: The TPG+ will remain in NIGHT mode if the light sensor is blocked by stickers, tape, etc.
Figure 4.
TPG+ light sensor location.