Apple Xserve RAID: Using RAID 1.2 Admin and Disk Utility User Manual

Page 32

Advertising
background image

32

Chapter 3

Monitoring Status and Changing Settings

To set up drive cache and controller cache:

1

Open RAID Admin and click Settings.

2

If necessary, enter the management password and click OK.

3

Click the Performance button.

4

To set up drive cache, click checkbox for the array for which you want to enable or
disable the drive cache.

5

To set up controller cache, click the button you want for Write Cache and Read Prefetch
for each controller.

•

Write Cache is used to complete data transactions from the host computer before
actually writing the data to the drives.

•

Read Prefetch anticipates that data should be retrieved from the arrays in sequential
order and “reads ahead.” In general, a large Read Prefetch setting is recommended
for video playback, and a small Read Prefetch setting is recommended for database
applications. Tuning the Read Prefetch setting may be required for optimal
performance, depending on your actual data.

6

Click OK.

7

In the confirmation window that appears, click OK.

Note: Drive cache and controller write cache are required for applications that have a
very high throughput, such as high-resolution video editing. UPS backup for drive
cache is highly recommended.

Advertising