Apple Xserve RAID: Using RAID 1.2 Admin and Disk Utility User Manual

Page 32

Advertising
background image

32

Chapter 3

Monitoring Status and Changing Settings

To set up drive cache and controller cache:

1

Open RAID Admin and click Settings.

2

If necessary, enter the management password and click OK.

3

Click the Performance button.

4

To set up drive cache, click checkbox for the array for which you want to enable or
disable the drive cache.

5

To set up controller cache, click the button you want for Write Cache and Read Prefetch
for each controller.

Write Cache is used to complete data transactions from the host computer before
actually writing the data to the drives.

Read Prefetch anticipates that data should be retrieved from the arrays in sequential
order and “reads ahead.” In general, a large Read Prefetch setting is recommended
for video playback, and a small Read Prefetch setting is recommended for database
applications. Tuning the Read Prefetch setting may be required for optimal
performance, depending on your actual data.

6

Click OK.

7

In the confirmation window that appears, click OK.

Note: Drive cache and controller write cache are required for applications that have a
very high throughput, such as high-resolution video editing. UPS backup for drive
cache is highly recommended.