m
Lens field of view
8 mm (equivalent to 50-mm lens on a 35-mm film
camera)
m
ISO
equivalent to approximately ISO 85
m
Focus range
4 feet to infinity
m
Aperture
ƒ2.8 to ƒ16
m
Shutter speed
1/30 second to 1/175 second
m
Flash range
4 feet to 9 feet
Temperature
m
Operating
0° to 40° C (32° to 104° F)
m
Storage (6 months)
–40° to 47° C (–40° to 117° F)
m
Transit (72 hours)
–40° to 65° C (–40° to 149° F)
m
Humidity
Classified as Class 1 equipment
Power requirements
m
Standby
<500 mW
m
Operating
<4.5 W
Operating environment
m
Temperature
0° to 40° C (32° to 104° F)
m
Humidity
20 to 95 percent, noncondensing
Electrical requirements
m
Internal power
3 AA batteries (3.6 V DC to 5.4 V DC)
m
External power
4.5 V DC/1.75 A to 8.0 V DC/1.0 A
Accessories
m
QuickTake 100 Travel Case (part number M2848G/A)
m
QuickTake 100 Battery Booster Pack (part number M2655G/A)
56