MBW CG200 User Manual

Page 26

Advertising
background image

24

Set height sensor location (Stringline height set at 20")

1.00"

Zero Grade

22.00"

20.00"

The front grade sensor is set to cut 1" below zero grade.

6. Front height sensor: Install sensor with potentiometer shaft facing forward. AdĆ

just sensor potentiometer shaft so that screw driver slot is horizontal. Remove

counterbalance weight from one of the three wands that are the same length.

Replace it with 1/4-20 x 1/2 Hex Head Bolt. Install wand in horizontal position.

Tighten wand bolt to secure wand to sensor.

7. Rear height sensor: Install sensor with potentiometer shaft facing forward. AdĆ

just sensor potentiometer shaft so that screw driver slot is horizontal. Install

wand in horizontal position. Tighten wand bolt to secure wand to sensor.

8. Check wand motion to ensure that wand base does not bind on sensor face.

Connect sensor plugs to pigtails from machine. The rear steering sensor cable

is marked #4 and has a single cable tie near the and.

SENSOR SHAFTS ARE VERY FRAGILE. REMOVE SENSORS BEFORE
TRANSPORTING OR STORING MACHINE.

Note: Only one height sensor can be used at a time. Front (grade) or rear (pour).

Only one steering sensor can be used at a time. Front or rear.

Advertising