Troubleshooting – Lukas SC 250 M User Manual

Page 19

Advertising
background image

19

9.3.2 Labels

All damaged and/or illegible labels (safety notices, type plate, etc.) must be renewed.

Procedure:

1. Remove damaged and/or illegible labels.
2. Clean surfaces with industrial alcohol.
3. Attach new labels.

Ensure that you attach the labels in the right position. If you are no longer sure about this,
then please contact your authorised LUKAS dealer or LUKAS itself.

10. Troubleshooting

Problem

Check

Cause

Solution

The blade arms cannot
be fully opened or closed

Insuffi cient
hydraulic fl uid in the
tool

Repair by an
authorised dealer,
by personnel
specially trained
by LUKAS, or by
LUKAS itself

Tool does not deliver the
specifi ed power

Device defective

The blade arms move
under load independent
without operating the
hand pump

Device defective

Slow movement of
the blade arms when
pumping in the off-load
condition

More than



pump strokes
required to open or
close the device?

Device defective

Rotary knob on the
control valve diffi cult
to turn under load
conditions

Device defective

The leaking of hydraulic
fl uid from the pump lever
or from the blade arm
piston rod

Defective piston rod
seal

Damage to the
piston

Material to be cut slides
between the blade arms
during cutting

Check pivot bolt

Pivot bolt not
tightened with the
prescribed torque

Tighten the pivot
bolt.

Tool head cannot be
turned

Tool under pressure Depressurise the

tool

Advertising