INSTALLATION - PLUMBING CONNECTIONS

WARNING: The system should only be

installed by qualified personnel. The

system should be installed in a clean,

dry, well ventilated area on a solid, level

surface.

FRESH AIR INTAKE LINE

Compressor Connections: 1/2 inch reinforced

tubing – provided

DRAIN

Type: 3/8 inch Clear PVC tubing - provided

DELIVERY LINE

Main Trunk Line: 1/2 inch copper or as site

layout dictates . Terminate in mechanical

room with 3/8 inch MPT. Trunk line to slope

1/4 inch /10 feet toward source compressor.

Operatory Branch Lines: 1/2 inch copper

1 . Remove compressor and accessories from

shipping skid .

2 . Install feet and mounting hardware .
3 . Move compressor to a dry, well ventilated area

on a solid, level surface .

4 . Connect drain tubing to hose barb fitting on

bottom of solenoid valve . Position opposite end

next to floor drain or over the edge of a floor sink

and secure into place . Ensure tubing is secured

to floor drain or sink as a sudden rush of exhaust

air can cause tubing to move .

NOTE: Do not place in contamination or

standing water . If floor drain is not available

contact distributor for assistance .

5 . Connect fresh air intake hose assemblies to

barbed fittings behind compressors . (See system

intake routing pictures below for correct tubing

routing) .

6. Connect office air supply line to 3/8” NPT air

outlet shut-off valve .

WARNING: Do not plumb intakes with
exhaust of vacuum system in the same
room.

JAir3

JAir5

JAir7

8.0 inch
intake

13.5 inch

intake

8.0 inch
intake

13.5 inch

intake

8.0 inch
intake

8.0 inch

intake

Equipment Alert:
Compessors are oil-less and require NO lubrication.

Equipment Alert:

For optimum performance and compressor longevity
route fresh air intake from a climate controlled area.
Tight bends in the air intake hoses may cause
them to collapse, potentially leading to premature
compressor failure.

To prevent moisture from entering the compressor...
Incoming fresh air temperature must not exceed room
temperature by more than 20 Fahrenheit or -6 Celsius

o

o

Equipment Alert:

Must meet local ventilation codes where system

is installed.