Battery isolation switch

The machine is provided with a KEY switch

which is used to isolate the battery and

therefore the electrical system, preventing

unauthorized use.

To enable the electrical system, Turn the

key switch to on position. Ensure that when

the machine is not in use, Turn the key

switch to off position.

Entering and leaving the work

platform

Always use three points of contact when

entering or exiting the platform, using the

handholds provided. For example, use two

hands and one foot. Use the step provided

on the base of the machine.

On entering the platform, ensure that the

gate is closed behind you.

Control box

The control box houses the platform raise

and lower controls.

Pressing the „UP‟ button raises the
platform.

Pressing the „DOWN‟ button lowers the
platform.

To avoid crushing and shearing hazards, a

delay feature is fitted which actuates when

the platform is lowered to the transport

position.

The platform will momentarily stop to

enable the operator to look around the

machine to determine whether any persons

are adjacent to the scissor mechanism.

After a time delay, the lowering control will

be re-enabled to permit the operator to

continue to lower to the transport position.

Take care to avoid repeated jerky

movements which could cause

unnecessary impact loads on the structure.

Emergency stop

An emergency stop button is provided on

the control box. Once depressed, this

isolates power to the raise and lower

functions.

To restore functionality, twist the

emergency stop button clockwise to

release the button.

Emergency lowering

To lower the platform in the event of an

emergency, a control is provided at the

chassis.

Pulling the knob below opens the lift valve,

which in pull, lowers the platform.

Battery charging

The machine

is supplied with a „built in‟

multi voltage automatic battery charger, for

voltages between 115v and 230v ac.

To charge the battery, follow these steps -

1. Connect the battery charger lead to the

machine.

2. Connect the battery charger to the

power supply (either 110V or 220V AC at

50 Hz depending on the mains supply).

3. The battery should be fully recharged

after a period of 12 hours, which is

indicated by the green Led illuminating on

the charging indicator.