Automatic shut-offs and circuit breakers, Rcd / elcb outlet (option) 5-1, Main circuit breaker 5-1 – Snorkel MHP34J(Bi-Energy Option) User Manual

Page 29: Outriggers 5-1, Main circuit breaker, 5-1, Outriggers, 5-1, Rcd/elcb outlet (option), 5-1

Advertising
background image

5. Automatic Shut-offs and Circuit Breakers

RCD/ELCB Outlet (option)

Figure 5.1 - RED/ELCB Outlet

The RCD (Residual Current Device) is located at
the base and will protect against short circuits to
earth. When there is a short circuit the RCD will
shut down the 230v AC power to the platform outlet.

To reset the outlet disconnect the power tool lead
from the platform box and reset the RCD at the
base.

If the problem persists call a trained service techni-
cian.

Main Circuit Breaker

Figure 5.2 - Main Circuit Breaker

There is only one circuit breaker, on a standard
MHP12/34J, that is accessible to the operator. Its
purpose is to protect the electrical circuits from
electrical overloads. When the circuit breaker trips
(pops out) push it back in then attempt to use the
MHP12/34J. If the circuit breaker trips a second
time, take the MHP12/34J out of service and refer
the problem to a qualified trained service techni-
cian for repair.

Outriggers

Figure 5.3 - Outriggers

The MHP12/34J cannot be raised unless the outrig-
gers are lowered and the lift enable light on the lower
control box is lit. Once the booms are raised from the
stowed position the outriggers become disabled un-
til the booms are stowed in the travel position.

MHP12/34J – 11447A

page 5 - 1

Advertising
This manual is related to the following products: