Self levelling stabiliser 11-2, Self levelling stabiliser operation 11-2, Air line to platform 11-2 – Snorkel MHP34J(Bi-Energy Option) User Manual

Page 56: Dual fuel 11-2, Work lights 11-2, Flashing light 11-2, Rcd / elcb ac outlet 11-2, Sandblast protection kit 11-2, Self levelling stabiliser -2, Self levelling stabiliser operation -2

Advertising
background image

enable it to completely re-charge the batteries and
automatically turn off after the cycle is completed.

Figure 11.4 - On-Board Battery Charger

The battery charger is fitted with an “interlock”. This
means that during the charging cycle all functions
on the machine are inoperative and will remain so
until the charger is switched off.

The charging cycle may last from 1 to 12 hours
depending on the state of the batteries. If the
charging cycle should exceed 16 hours ( indicating
a fault) the charger will automatically shut down
and the batteries should be checked.

DO NOT re-charge the batteries unless the
electrolyte level has been checked.

DO NOT allow smoking, flames or sparks around
batteries.

DO ENSURE the covers are in the open position
during charging to allow gasses to escape.

Self Levelling Stabiliser

This option allows the stabilisers to be lowered and
the unit to be levelled by operating one switch at the
lower control station.

Figure 11.5 - Stabiliser Operation Switches

Self levelling stabiliser operation

To operate the master key switch



must be on. Se-

lect stabiliser using the Stabiliser/Boom switch

€

.

(See Figure 11.5)

Momentarily (3 - 6 seconds) press the stabiliser
lower switch



(see Figure 11.5), this will lower all

four stabilisers and allow the unit to “self level”. The
boom can now be operated in the normal manner.

When raising the stabilisers the switch



must be

held in the raise mode until all four stabilisers are
fully raised into their stowed position.

Air Line To Platform

This consists of

*

” pressure flex yellow hose rated at

150 psi working pressure, fitted with quick discon-
nect couplers at each end .

Dual Fuel

This option consists of an AC motor rated at either
110 or 230 volts AC 50/60Hz mounted under the fi-
berglass covers. A selector switch is used to change
from gasoline to electric. The same controls are
used to stop and start the electric motor.

This option is used in shopping malls and other built
up areas.

Work Lights

Rubber encased work lights can be fitted to the
platform guardrails. The lights are swivel mounted
and each has its own switch.

Flashing Light

For this option see Chapter 2 page 3

RCD/ELCB AC Outlet

A 3 core wire rated at 600 volts AC 15 amps is run
up the booms as standard.

For this option see Chapter 2 Page 3.

Sandblast Protection Kit

This option consists of a bellows type cover fitted to
each boom cylinder shaft. The bellows prevent
sand and paint from damaging the cylinder rods
and seals, and thus prevent hydraulic oil leaks.

D O N OT p a i n t o r s a n d bl a s t f ro m a n
MHP12/34J unless the cylinder rods are
protected by bellows.

page 11 - 2

MHP12/34J – 11447A

11. Options

CAUTION

Advertising
This manual is related to the following products: