Maintenance and cleaning, Accessories – IKA RV 10 control FLEX auto User Manual

Page 65

Advertising
background image

65

Maintenance and cleaning

The device is maintenance-free. It is subject only to the natural wear and
tear of components and their statistical failure rate.

The seal on the glass condenser should be checked at regular intervals
and replaced if necessary.

For cleaning disconnect the main plug.

To clean the device use only water with a detergent that contains tensi-
des, or use isopropylalcohol for stubborn soiling.

Spare parts order

When ordering spare parts, please give:
- Machine type
- Manufacturing number, see type plate
- Item and designation of the spare part,
see www.ika.com, spare parts diagram and spare parts list

.

Repair

In case of repair the device has to be cleaned and free from any materials
which may constitute a health hazard. For this use the "certificate of

compliance", download the form from the IKA

®

website www.ika.

com.

If you require servicing, return the appliance in its original packaging.
Storage packaging is not sufficient. Please also use suitable transport
packaging.

Safety lift
The safety lift must be checked daily prior to operation!
After a long period of inactivity (approx. four weeks), use the motor to
move the lift to the top or bottom position several times prior to starting
distillation. (See the section entitled Safety Instructions - Safety Lift)! If the
safety lift is not working, please contact the IKA

®

Service department.

Accessories

RV 10.1

NS 29/32 Vertical glassware (1)

RV 10.10

NS 29/32 Vertical glassware, coated (1)

RV 10.2

NS 29/32 Diagonal glassware (2)

RV 10.20

NS 29/32 Diagonal glassware, coated (2)

RV 10.700

NS 29/42 Vertical glassware (1)

RV 10.710

NS 29/42 Vertical glassware, coated (1)

RV 10.800

NS 29/42 Diagonal glassware (2)

RV 10.810

NS 29/42 Diagonal glassware, coated (2)

RV 10.900

NS 24/40 Vertical glassware (1)

RV 10.910

NS 24/40 Vertical glassware, coated (1)

RV 10.1000

NS 24/40 Diagonal glassware (2)

RV 10.1010

NS 24/40 Diagonal glassware, coated (2)

RV 10.3

Vertical-intensive condenser with manifold(1)

RV 10.30

Vertical-intensive condenser with manifold, coated (1)

RV 10.4

Dry ice condenser (2)

RV 10.40

Dry ice condenser, coated (2)

RV 10.5

Vertical-condenser with manifold and cut-off valve (no picture)

RV 10.50

Vertical-condenser with manifold and cut-off valve, coated (no picture)

RV 10.6

Vertical-intensive condenser with manifold and cut-off valve

for reflux distillation (3)

RV 10.60

Vertical-intensive condenser with manifold and cut-off valve

for reflux distillation (3)

HB 10.1

Protection shield (Heating bath HB 10) (1)

HB 10.2

Protection cover (Heating bath HB 10) (2)

RV 10.70

NS 29/32 Steam pipe

RV 10.71

NS 24/29 Steam pipe

RV 10.72

NS 29/42 Steam pipe

RV 10.73

NS 24/40 Steam pipe

RV 10.74

NS 29/32 Steam pipe, short,

for reflux distillation

RV 10.75

NS 24/29 Steam pipe, short,

for reflux distillation

RV 10.76

NS 29/42 Steam pipe, short,

for reflux distillation

RV 10.77

NS 24/40 Steam pipe, short,

for reflux distillation

Advertising