SECTION 4 - BOOM & PLATFORM

4-12

– JLG Lift –

3120788

the meter for the time it takes the output to go from 0
current to maximum current. This is ramp up time.
Adjust P1 until this time matches the time in table 2.
Rotating the adjustment potentiometer clockwise
will increase ramp time. To set the ramp down time,
hold the telescope function switch and watch the
time it takes the output to go from the maximum cur-
rent down to 0 current. This is the ramp down time.
Adjust P2 until this time matches the setting in table
2. Rotating the adjustment potentiometer clockwise
will increase the ramp time.

NOTE: No ramp needed for drive forward and reverse. THe

drive pump is a slow reacting pump with internally
built in ramp up and down times.

Table 4-2. Flow Control Card Settings

S Models

Function

Minimum Current

Maximum Current

Lift Up

400 mA

1320 mA

Lift Down

500 mA

1500 mA

Swing Right

400 mA

935 mA

Swing Left

400 mA

935 mA

Flow Control

700 mA

1600 mA

Drive Forward (Deutz)

820 mA

1120 mA

Drive Reverse (Deutz)

820 mA

1120 mA

Drive Forward (Ford)

820 mA

1200 mA

Drive Reverse (Ford)

820 mA

1200 mA

Figure 4-9. Control Card

Table 4-3. Flow Control Card Ramp Time

Function

Ramp Time

Lift Up

Ramp Up Time = 2:00 sec.
Ramp Down Time = 2:00 sec.

Lift Down

Ramp Up Time = 3:00 sec.
Ramp Down Time = 2:00 sec.

Swing Right

Ramp Up Time = 3:50 sec.
Ramp Down Time = 2:00 sec.

Swing Left

Ramp Up Time = 3:50 sec.
Ramp Down Time = 2:00 sec.

Drive Forward

Ramp Up Time = none
Ramp Down Time =none

Drive Reverse

Ramp Up Time =none
Ramp Down Time = none

Flow Control

(Tele, Rotate, Jib)

Ramp Up Time = 3:00 sec.
Ramp Down Time = 0:00 sec.