SECTION 6 - JLG CONTROL SYSTEM (S/N 61718 TO PRESENT)

3120788

– JLG Lift –

6-39

TWR LENGTH SENSOR ONE VALUE
OUT OF RANGE LOW

This fault is reported by the Ground module when the length sensor value is
outside the constant data limit

TWR LENGTH SENSOR TWO VALUE
OUT OF RANGE HIGH

This fault is reported by the Ground module when the length sensor value is
outside the constant data limit

TWR LENGTH SENSOR TWO VALUE
OUT OF RANGE LOW

This fault is reported by the Ground module when the length sensor value is
outside the constant data limit

TWR ANGL1 INVALID ANGLE

Tower boom angle sensor #1 out of range

TWR ANGL2 INVALID ANGLE

Tower boom angle sensor #2 out of range

INVALID ANGLE SENSOR #1 MODEL

Wrong tower angle sensor Mfgr. Installed on a 1250AJP (Must be a Rieker, not
Spectron)

INVALID ANGLE SENSOR #2 MODEL

Wrong tower angle sensor Mfgr. Installed on a 1250AJP (Must be a Rieker, not
Spectron)

MAIN ANGL1 INVALID ANGLE

Main boom angle sensor #1 out of range

MAIN ANGL2 INVALID ANGLE

Main boom angle sensor #2 out of range

MAIN ANGLE SENSOR NOT DETECT-
ING ANGLE CHANGE

The main boom is being commanded to move and the main angle sensors are
not detecting any movement

MAIN ANGLE MOVEMENT WITHOUT
CMD

The main boom angle is changing without a main lift command

WRONG TWR TELE RESPONSE

The tower telescope is moving in the opposite direction the user is command-
ing.

WRONG TWR LIFT RESPONSE

The tower lift is moving in the opposite direction the user is commanding

TWR CYL ANGLE SENSOR OUT OF
RANGE LOW

The tower cylinder angle sensor is below 4721 A/D counts

TWR CYL ANGLE SENSOR OUT OF
RANGE HIGH

The tower cylinder angle sensor is above 29535 A/D counts.

TWR CYL ANGLE NOT DETECTING
ANGLE CHANGE

The cylinder angle is not changing during a tower lift up/down user command.

TWR CYL ANGLE MOVEMENT WITH-
OUT CMD

The cylinder angle is changing without a tower lift command

MAIN TRN ANGLE SW FAILED

The system detected a disagreement of the N.O. vs N.C. contacts on the main
boom angle switch.

TWR TRN SW DISAGREEMENT

The system detected a disagreement between the tower boom length switch
and the tower length sensors.

TRN DUAL CAP SWITCHES BAD

The system detected both the Dual capacity and the transport switches are
bad.

TRN DUAL CAP BAD TRANSITION

The system detected that the Dual capacity or the transport switches changed
state out of order.

MAIN TRN LEN SW DISAGREEMENT

The system detected a disagreement between the main boom transport length
switches.

DCAP LEN SW DISAGREEMENT

The system detected a disagreement between the main boom dual capacity
length switches.

MAIN BOOM TRN ANGLE SW/SEN-
SOR DISAGREEMENT

The system detected a disagreement between the main boom transport angle
switch and the main boom angle sensors.

CYL ANGLE SENSOR/SW DISAGREE-
MENT

The system detected a disagreement of the tower angle input from the BLAM
and the tower cylinder angle sensor.

Table 6-3. Help Fault Codes, Displayed Faults, and Descriptions - S/N 66995 to Present

Fault Flash

Code

Communicated (Displayed on

Analyzer) Fault

Description

Priority