8 major component weights, 9 pressure settings, Major component weights -3 – JLG T500J Service Manual User Manual

Page 17: Pressure settings -3, Component weights -3, 8 major component weights 1.9 pressure settings

Advertising
background image

SECTION 1 - SPECIFICATIONS

3121200

– JLG Lift –

1-3

1.8 MAJOR COMPONENT WEIGHTS

1.9 PRESSURE SETTINGS

Cold temperatures have a significant impact on pressure
readings. JLG Industries Inc. recommends operating the
machine until the hydraulic system has warmed to normal
operating temperatures prior to checking pressures. JLG
Industries Inc. also recommends the use of a calibrated
gauge. Pressure readings are acceptable if they are within
± 5% of specified pressures.

Table 1-9. Component Weights

Component

Pounds

Kilograms

Frame (bare)

597

271

Frame - CE, Aus (bare)

892

382

Turntable (bare)

262

119

Booms & Cylinders Assy.

1891

859

Main Boom

957

435

Engine Assy. (Incl. Tray)

116

53

Engine (bare)

57

26

Axle

221

100

Table 1-10. Pressure Settings

Circuit

PSI

Bar

Main Relief

2950

203.5

Telescope In

2850

196.5

Telescope Out

2400

166

Platform Level Up

2800

193

Platform Level Down

2000

138

Swing Right

600-800

41-55

Swing Left

600-800

41-55

Outrigger Up

2500

172.5