Limit switches - ce machines -9, Or figure 4-7 – JLG 460SJ Service Manual User Manual
Page 273
Advertising

SECTION 4 - BOOM & PLATFORM
3120895
– JLG Lift –
4-9
Figure 4-7. Limit Switches - CE Machines
SWITCH TO ACTIVATE WHEN BOOM IS EXTENDED
84.375"
± 1" (214.3 ± 2.5 cm).
SEE VIEW A FOR SWITCH ORIENTATION.
SEE DETAIL B
SEE DETAIL A
DETAIL B
DETAIL A
ABOVE HORIZONTAL SWITCH
TO ACTIVATE WHEN BASE
BOOM IS RAISED 5
° TO 10°
ABOVE HORIZONTAL. SWITCH
TO RESET WHEN BASE BOOM
LOWERED 1
° BELOW TO 4°
ABOVE HORIZONTAL.
SUGGESTED
INITIAL ARM
POSITION SETTING
MOUNTING
SURFACE
VIEW A
90
.0°
0271163-F
Advertising