SECTION 6 - JLG CONTROL SYSTEM (S/N 61718 TO PRESENT)

6-44

– JLG Lift –

3120895

BLAM SENSOR SUPPLY OUT OF
RANGE HIGH

Indicates that the supply voltage for the boom angle sensors is above the
expected range. An EMS cycle is required.

BLAM SENSOR SUPPLY OUT OF
RANGE LOW

Indicates that the supply voltage for the boom angle sensors is below the
expected range. An EMS cycle is required.

LENGTH SENSOR REF VOLTAGE
HIGH

Indicates that the supply voltage for the boom length sensors is above the
expected range. An EMS cycle is required.

LENGTH SENSOR REF VOLTAGE
LOW

Indicates that the supply voltage for the boom length sensors is below the
expected range. An EMS cycle is required.

BLAM HIGH RES A/D FAILURE

The high resolution Analog to digital converter in the BLAM module has failed.
An EMS cycle is required.

CHASSIS SENSOR SUPPLY OUT OF
RANGE LOW

Indicates that the supply voltage for chassis sensors is below the expected
range. An EMS cycle is required.

CHASSIS SENSOR SUPPLY OUT OF
RANGE HIGH

Indicates that the supply voltage for chassis sensors is above the expected
range. An EMS cycle is required.

BLAM BACKUP COMMUNICATIONS
LINK FAULTY

Reported if the backup communications link to the BLAM failed the test at
startup.

BLAM BACKUP COMMUNICATIONS
LOST - HYDRAULICS SUSPENDED

The backup communications link to the BLAM module was activated but could
not establish/maintain communications with the BLAM.

4150461-E

Table 6-3. Help Fault Codes, Displayed Faults, and Descriptions - S/N 66995 to Present

Fault Flash

Code

Communicated (Displayed on

Analyzer) Fault

Description

Priority