SECTION 5 - EMERGENCY PROCEDURES

3120825

– JLG Sizzor –

5-1

SECTION 5. EMERGENCY PROCEDURES

5.1

GENERAL

This section provides information on the procedures to be
followed and on the systems and controls to be used in
the event an emergency situation is encountered during
machine operation. Prior to operation of the machine and
periodically thereafter, the entire operating manual, includ-
ing this section, should be reviewed by all personnel
whose responsibilities include any work or contact with
the machine.

5.2

EMERGENCY TOWING PROCEDURES

Although towing the machine is prohibited, when not
equipped with a tow package, provisions for moving the
machine, in case of a malfunction or power failure, have
been incorporated. The following procedures are to be
used ONLY for emergency movement to a suitable main-
tenance area.

1.

Chock wheels securely.

2.

Disengage (reverse) the disconnect cap on each
drive torque hub by removing the two attaching cap-
screws, turning the cap around, and reinstalling and
tightening the capscrews.

3.

Remove chocks and move the machine to an appro-
priate maintenance area, using suitable equipment
for assistance.

After moving machine, complete the following proce-
dures:

1.

Position machine on a firm, level surface.

2.

Chock wheels securely.

3.

Return disconnect caps to normal (engaged) posi-
tion.

4.

Remove chocks from wheels.

5.3

EMERGENCY CONTROLS AND THEIR
LOCATIONS

Emergency Stop Switch

At platform controls, red Ignition/Emergency Stop switch
when depressed, it will immediately stop the machine.

Ground Control Station

The Ground Control Station is located on the left side of
the machine frame. The controls on this panel provide the
means for overriding the platform controls and for control-
ling the platform lift up and down and ignition functions
from the ground. Position the Ignition/Emergency Stop

switch to ON, position the PLATFORM/ GROUND SELECT
switch to the GROUND position and operate the appropri-
ate switch, LIFT or IGNITION.

IF MACHINE IS EQUIPPED WITH PLATFORM EXTENSION OR TRA-
VERSING DECK, RETRACT DECK BEFORE LOWERING PLAT-
FORM.

Manual Descent - (Engine/Pump Failure -
Platform Controls)

In the event of engine/pump failure while operating the
machine from the platform console, the following proce-
dure should be followed to lower the platform. Turn the
POWER ON switch to ON. Place and hold the lift control
switch to down. When platform is completely down, return
lift control switch to center off and position power on
switch to off.

Manual Descent

-

(Engine/Pump Failure -

Ground Controls)

The following procedure should be used to lower the plat-
form from the ground controls in the event of engine/
pump failure.Turn MAIN POWER switch to ON and PLAT-
FORM/GROUND SELECT switch to GROUND. For battery
powered machines, position MAIN POWER switch to
GROUND. Place LIFT control switch to DOWN. When plat-
form is completely down, return LIFT control switch to
center OFF and position MAIN POWER switch to OFF.

Manual Descent - (Complete Loss of Power)

The manual descent valve is used, in the event of total
power failure, to lower the platform using gravity. The
manual descent handle is located on the center rear of the
machine frame, just above the first set of scissor arms.
The handle is connected, by a cable, to the manual
descent valve on the lift cylinder. Pulling the manual
descent handle opens the valve, lowering the platform.