Options – JLG TF6-42 Parts Manual User Manual

Page 436

Advertising
background image

OPTIONS

TF6-42

91504001

12-6

Figure 12-1 Heater Option Assembly

E

F

A

B

C

D

A

B

GND HSW

BAT HSW

BAT WSW

HIG WSW

LOW WSW

WAS WSW

PAR WSW

BAT WSW

BAT HSW

GND HSW

PAR WSW

WAS WSW

LOW WSW

HIG WSW

HIG HWS

MED HWS

LOW HWS

GND HWS

HIG HWS

MED HSW

LOW HWS

GND HWS

BAT HSW

GND HSW

PAR WSW

WAS WSW

LOW WSW

HIG WSW

GND HSW

BAT HSW

PAR WSW

HIG WSW

LOW WSW

GND FAN

BAT FAN

WAS WSW

LOW

HSW

BAT

HSW

NOT USED

HIG

HSW

MED

HSW

L

M

R C

B

1

2

3

4

5

4

6

7

5

9

10

11

12

13

14

15

16

23

24

25

23

26

11

27

28

29

30

31

32

33

34

4

9

29

30

35

36

37

17

18

19

SL_SWB

WL_SWB

HTR_SW

WL2

8

20

REV_ALARM

WARN_LT_CK

AUX_ELEC1

AUX_ELEC2

OPT

FAN/HTR

W/W

LIGHTS

ACC

FAN

/HT

R

25

A

W

/W

25

A

LIG

HTS

25

A

RELA

YS

10

A

GA

U

GE

S

10

A

ST

EER 10

A

SP

ARE

_B

AT

25

A

K

E

Y

15

A

HO

RN

10

A

OPT_P

WR

30

A

OPT1 10

A

OPT2 15

A

OPT3 15

A

SW1-86

SW2-87A

SW2-86

SW1-87A

GND85

SPARE_COIL

OPT1

OPT2

OPT3

GND

1

GND

2

GND

3

SPARE_BAT

OPEN CAB ONLY

RETURN LINE

SECURE HEATER

HOSES BY TIE

WRAPPING TO

NEARBY HOSE

FROM THE OIL

COOLER

SUPPLY

LINE

CUTAWAY VIEW OF RH

CONSOLE TO SHOW WATER

VALVE MTG.

HEATER FAN SWITCH

HARNESS CONNECTIONS

ITEMS 26 & 37

REMOVE PANEL

COVER AND

DISCARD

(REUSE

EXISTING

HARDWARE)

USE ON BOTH

OUTLETS ON

PLENUM

RETURN

RETURN

SUPPLY

SUPPLY

ATTACH

HEATER TO

WELD NUTS

ON CAB

FLOOR

ATTACH BAT HSW & GND

WIRES TO BAT HSW AND GND

ON INSTRUMENT PANEL

THESE WIRES

WILL NOT BE

USED

WIPER-WASHER-

HEATER DASH

HARNESS

ATTACH TO BLOWER

SPEED SWITCH

ATTACH TO

HEATER

WIRING

HEATER HARNESS

ATTACH TO BLOWER

SPEED SWITCH

THESE WIRES

WILL NOT BE

USED

WIPER-HEATER

OPT HARNESS

S/N 0160013983 & After

Advertising